Flash Point Certified Reference Materials


ARO Scientific has created certified reference materials to support safety testing for liquid fuels, liquid lubricants, and other flammable materials.
Why is flash point important?
The flash point of a liquid is defined as the lowest temperature, corrected to a barometric pressure of 101.3 kPa, at which a substance generates enough vapor to form a vapor/air mixture that can be ignited with an ignition source. Flash point data is used for assessing the safety of liquid fuels, liquid lubricants, and their mixtures, for example, shipping and safety regulations to define “flammable” materials. Flash point data can also indicate the possible presence of highly volatile and flammable material in a relatively non-volatile or non-flammable material.
-
Flash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-SWS-COC30
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-SWS-COC50
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC30
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-SWS-COC20
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-SWS-COC40
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC10
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified (HMA HMG) UN1202 -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC20
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC40
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC50
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-SWS-COC10
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-SWS-PMCC60
- OEM Parts None Available
In stockFurther informationFlash Point Secondary Working Standard, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
ABEL Flash Pont Certified Reference Material, Jet A1- UOM .25L
- Alpha Part ARO-CRM-ABKR01
- OEM Parts None Available
In stockFurther informationABEL Flash Pont Certified Reference Material, Jet A1
ISO 17034 Certified (HMA HMG) UN1863 -
Flash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-CRM-COC30
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-CRM-PMCC40
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-CRM-COC20
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-CRM-COC40
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-CRM-PMCC10
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-CRM-PMCC30
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92- UOM 80ML
- Alpha Part ARO-CRM-COC10
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Lubricant, Cleveland Open Cup (COC), ASTM D92- UOM .25L
- Alpha Part ARO-CRM-FCLU01
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Lubricant, Cleveland Open Cup (COC), ASTM D92
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM 80ML
- Alpha Part ARO-CRM-PMCC20
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified -
Flash Point Certified Reference Material, Diesel, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A- UOM .25L
- Alpha Part ARO-CRM-PMGO01
- OEM Parts None Available
In stockFurther informationFlash Point Certified Reference Material, Diesel, Pensky-Martens Closed Cup (PMCC), ASTM D93, Procedure A
ISO/IEC 17025 & ISO 17034 Certified (HMA HMG) UN1202